- Before
- Owns the quarterly and annual reliability filings, with three weeks of reconciliation each quarter. “I trust the index. I don't trust the 214 records under it.”
- Now
- Opens the calendar on the one day that needs a decision, accepts each fix with its meter evidence, and marks a major event day with the calculation already attached.
One storm day, from the outage records to a filed Q3 report
Lumina Utilities serves 1,284,600 electricity customers on 1,146 feeders across five regions. Its Q3 2026 reliability report is due to the Regional Energy and Water Commission (REWC) on 31 October. On 19 August a line of thunderstorms crossed Harbour and Eastern Hills. Here is what happens next, screen by screen, in the working solution.
- 01Morning, 18 days to file
The calendar opens on the day that needs a decision
Nadia Rahman · Reliability engineerNine months sit on one reliability calendar, each day coloured by customer minutes lost. Year-to-date SAIDI excluding major event days is 62.2 minutes, 11.2 over the 51.0-minute target to 30 September. Last night's run put one day at the top: Wed 19 Aug, 14.2 minutes, 3.5 times the major event day threshold, with 9 record exceptions that change its minutes.
“Overnight run 02:10 · 6 agents · ready 02:40”
- 02Overnight
Every outage record proved against the meters
Outage record checkerThe checker has matched 2,671 records this year to 41.6 million meter events. On the storm day it found three duplicates, each one interruption logged twice, and three restore times the meters disprove. OUT-26-48233 on feeder breaker CB-31 shows a 23:59 placeholder left open when the crew moved on; 1,846 of 1,902 meters report power back between 17:41 and 17:47, so it proposes 17:44.
Not trying to lower the number: EX-0818 moves a start time from the first customer call at 15:40 to the last-gasp messages at 15:12 — it adds 28 minutes.
- 03One click
Nine fixes accepted, the indices recomputed
Nadia Rahman · Reliability engineerNadia accepts the 9 fixes. The customer count checker had found transformer T-55810 serves 148 meters, not the 412 customers taken from T-55801, and a 2 min 55 s operation on recloser R-2251-3 comes out of SAIDI and SAIFI as momentary. The day goes from 218 to 214 interruptions, 104,374 to 98,900 customers and 14.2 to 13.0 minutes; year-to-date SAIDI falls from 62.2 to 61.0.
“Run by the record checker and index calculator · accepted by Nadia Rahman”
- 04Set on 2 January
The threshold, from five years of daily SAIDI
Major event day assessorThe 2026 threshold comes from 1,811 days with interruptions in 2021–2025, with 15 days with none left out. The mean of ln(daily SAIDI) is α = −1.622 and the standard deviation β = 1.211, so T_MED = e^(α + 2.5β) = 4.08 minutes, fixed for the year. Only 10 of the 1,811 days were above it; earlier years flagged 2 to 4 major event days each.
“A day in 2026 whose daily SAIDI is above 4.08 minutes is a major event day.”
- 05The decision
19 August marked a major event day
Nadia Rahman · Reliability engineerAt 13.0 minutes the day is 3.19 times the threshold, and Nadia marks it. The assessor counts 37 interruptions that ran past midnight to 19 August, the day they began, and gathers the weather and crew evidence. SAIDI excluding major event days falls from 61.0 to 48.0 minutes, SAIFI from 0.742 to 0.665 and CAIDI from 82.2 to 72.2 — now 3.0 minutes inside the target.
“Major event day · excluded from the indices excluding major event days; kept in the all-days figures.”
- 06The day file
The justification note, with its six sources
Major event day assessorThe day file shows the storm hour by hour, from 13:00 on 19 August to the last restore at 06:10 the next morning, the largest interruptions with the crew's cause, and the threshold test. The evidence is cited: the Cape Lumen weather station with gusts of 96 km/h at 14:20, 1,240 lightning strikes, 31 Lumina crews and 12 from Tasman Line Services, and the 9 accepted record corrections.
“Before the test, each outage record for the day was checked against smart meter power-off and power-on events, and 9 corrections were accepted, which moved the day from 14.2 to 13.0 minutes.”
- 07A second try
A heatwave day below the threshold stays in
Major event day assessorOn Sat 2 May a heatwave overloaded transformers in Central and Riverside: 61 interruptions, 31,240 customers, 3.91 minutes of daily SAIDI — 0.96 times the threshold. Asked to exclude it, the assessor refuses and says why. The day counts in every index, and can be described in the report narrative instead.
“2 May cannot be excluded. Its daily SAIDI of 3.91 min is below the 2026 threshold of 4.08 min.”
- 08Outside the storms
The feeders that really lose the minutes
Nadia Rahman · Reliability engineerRanked by customer minutes excluding major event days, F-1102 Harbour Road 3 leads with 1,290,486, a feeder SAIDI of 253 minutes, 3,164 customers with three or more interruptions and equipment failure as the top cause. F-3108 Cape Lumen, first on all days, drops to fifteenth once the storm is set aside. Nadia sends F-1102 to the November capital planning review with its year.
Feeder F-1102: “214,000 customer minutes on the 19 Aug storm (major event day candidate).”
- 09The draft
The Q3 report, both index sets, every number cited
Report writerThe report writer drafts the Q3 2026 report in the REWC template: summary, method, major event days, data quality, worst-performing feeders, notable events and Appendix A with the justification note. It shows 61.0 minutes across all days and 48.0 excluding major event days, against 51.0. The data-quality section records 2,667 sustained interruptions and 50 corrections accepted this year; source records are unchanged.
“Drafted 13 Oct 02:40 · every number links to its source · re-drafts when a record changes”
- 10Signed, then filed
Graham signs, with the meaning of his signature; Leah files
Graham Oyelaran · Head of Network PerformanceGraham opens the signature with SAIDI excluding major event days at 48.0 minutes and 1 major event day, 19 August, in front of him. He signs as Head of Network Performance on 21 Oct at 09:14. Leah Fontaine in regulatory affairs files with the REWC and gets receipt REWC-RR-2026-Q3-0417.
Meaning of signature: “I have reviewed the indices, the major event day exclusions and their justification, and approve this report for filing.”